Vet Cutter Electrosurgery 160W with monopolar and bipolar capabilities with bipolar kit

Ex VAT £1,216.70
Code: VCE160KIT

Electrosurgery MB 160D - mono-bipolar system with BIPOLAR KIT 160W

This is a frequency electrosurgical unit suitable for minor and medium surgery.

Pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and when used with forceps it produces BIPOLAR coagulation.

The digital reading of delivered power and the monitoring of operative function by microcontroller guarantees absolute reliability of working conditions.

MB 160D allows a highly professional surgery through ergonomics and safety features. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrodes.

Possibility to control the output functions and the delivery of output power by the working handle, allows full surgical concentration without having to divert attention away from the surgical field.

Features:
- minimum invasive surgery
- possibility to use bipolar forceps
- possibility to use split neutral electrodes
- memorisation of the last used settings
- power activation by pedal and/or handle
- digital adjustment and indication of the output power
- adjustment of the acoustic indicator intensity

This system includes MAIN UNIT and BIPOLAR ACCESSORY KIT

• Contains VCE160 (Main Electrosurgery Unit)

• Bipolar cable - Vet Cutter Bipolar Cable Wirh Adaptor For 120D And 160D (VCE011)

• Vet Cutter Straight Bipolar Forceps 15cm / 0.5mm Points (VCE002)

• Vet Cutter Autoclavable Handle & Cable 3 Pin (Suitable For VCE160) (VCE102)

Standard accessories

• MB single use two button handle (but recommended to use the VCE102 included with the kit as it is re-usable and autoclavable)
• Waterproof foot-switch (usable as alternative to handle)
• MB flat neutral plate with cable
• Kit of 10 autoclavable electrodes
• Power cable: 2M

Technical Specifications
• Max output power CUT: 160 W - 250 Ohm
• Max output power BLEND: 120 W - 200 Ohm
• Max output power FORCED COAG: 100 W - 150 Ohm
• Max output power SOFT COAG: 80 W - 100 Ohm
• Max output power BIPOLAR: 60 W - 100 Ohm
• Working frequency: 600 kHz
• Patient circuit: F
• Selectable input voltage: 115 - 230 Vac
• Mains frequency: 50 - 60 Hz
• Electrical input power: 350 VA
• Size WxHxD mm: 254 x 104 x 288
• Weight: 5 kgs
• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
• Safety: EN60601-1, EN60601-1-2, EN60601-2-2,
• Electrical Class: I CF; MDD 93/42/EC Class: II b

 

Service Interval: 12 months

Average Rating

0 Reviews
No reviews yet
5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0

Write a Review

You must be signed in to leave a review.

Write a Review

You May Also Like
New In