Vet Cutter Electrosurgery 120W with monopolar and bipolar capabilities with bipolar kit

Ex VAT £915.00
Code: VCE001KIT

Electrosurgery MB 120D - mono-bipolar system with BIPOLAR KIT 120W

This is a frequency electrosurgical unit suitable for minor and medium surgery.

Pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and when used with forceps it produces BIPOLAR coagulation.

The digital reading of delivered power and the monitoring of operative function by microcontroller guarantees absolute reliability of working conditions.

MB 120D allows a highly professional surgery through ergonomics and safety features. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrodes.

Possibility to control the output functions and the delivery of output power by the working handle, allows full surgical concentration without having to divert attention away from the surgical field.

Features:
- minimum invasive surgery
- possibility to use bipolar forceps
- possibility to use split neutral electrodes
- memorisation of the last used settings
- power activation by pedal and/or handle
- digital adjustment and indication of the output power
- adjustment of the acoustic indicator intensity

This system includes MAIN UNIT and BIPOLAR ACCESSORY KIT

• Contains VCE120 (Main Electrosurgery Unit)

• Bipolar cable - Vet Cutter Bipolar Cable Wirh Adaptor For 120D And 160D (VCE011)

• Vet Cutter Straight Bipolar Forceps 15cm / 0.5mm Points (VCE002)

• Vet Cutter Autoclavable Handle & Cable 3 Pin (Suitable For VCE120) (VCE103)

Standard accessories

• Includes MB "single use" two button handle (recommended to buy VCE103 re-usable and autoclavable handle with this unit)
• Waterproof foot-switch (usable as alternative to handle)
• MB flat neutral plate with cable
• Kit of 10 autoclavable electrodes
• Power cable: 2M

 

Technical Specifications
• Max output power CUT: 120 W - 250 Ohm
• Max output power BLEND: 90 W - 200 Ohm
• Max output power FORCED COAG: 80 W - 150 Ohm
• Max output power SOFT COAG: 60 W - 100 Ohm
• Max output power BIPOLAR: 40 W - 100 Ohm
• Working frequency: 600 kHz
• Patient circuit: F
• Selectable input voltage: 115 - 230 Vac
• Mains frequency: 50 - 60 Hz
• Electrical input power: 300 VA
• Size WxHxD mm: 254 x 104 x 288
• Weight: 5 kgs
• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
• Safety: EN60601-1, EN60601-1-2, EN60601-2-2,
• Electrical Class: I CF; MDD 93/42/EC Class: II b

Service Interval: 12 months